Deye Single Phase Hybrid Inverter | 3-6kW | 2 MPPT | LV Battery Supported SUN-3/3.6/5/6K-SG04LP1-EU-SM1/SM2

Short Description:

 

  • Colorful touch LCD, IP65 protection degree
  • AC couple to retrofit existing solar system
  • Max. 16 pcs parallel for on-grid and off-grid
    operation; Support multiple batteries parallel
  • Max. charging/discharging current of 140A
  • 6 time periods for battery charging/discharging
  • Support storing energy from diesel generator

 


Product Detail

Product Tags

 

Model SUN-3K-SG04LP1-24-EU-SM1 SUN-3K-SG04LP1-EU-SM1 SUN-3.6K-SG04LP1-EU-SM2 SUN-5K-SG04LP1-EU-SM2 SUN-6K-SG04LP1-EU-SM2
Battery Input Data
Battery Type Lead-acid or Lithium-ion
Battery Voltage Range(V) 20-30 40-60
Max.Charging Current(A) 140 70 90 120 135
Max.Discharging Current(A) 140 70 90 120 135
Charging Strategy for Li-ion Battery Self-adaption to BMS
Number of battery input 1
PV String Input Data
Max. PV Access Power (W)
6000 6000 7200 10000 12000
Max PV Input Power(W) 4800 4800 5760 8000 9600
Max PV Input Voltage(V) 500
Start-up Voltage(V) 125
MPPT Voltage Range(V) 150-425
Rated PV Input Voltage(V) 370
Max Operating PV Input Current(A) 18 18+18
Max Input Short-Circuit Current(A) 27 27+27
No.of MPP Trackers/No.of String Per MPP Tracker 1/1 2/1+1
AC Input/Output Data
Rated AC Input/Output Active Power(W) 3000 3600 5000 6000
Max AC Input/Output Apparent Power (VA) 3300 3960 5500 6600
Rated AC Input/Output Current(A) 13.7/13.1 16.4/15.7 22.8/21.8 27.3/26.1
Max AC Input/Output Current(A) 15/14.4 18/17.3* 25/24 30/28.7
Max Continuous AC Passthrough (grid to load)(A) 35 40
Peak Power (off-grid)(W) 2 times of rated power,10s
Rated Input/Output Voltage/Range(V) 220V/230 0.85Un-1.1Un
Grid Connection Form L+N+PE
Rated Input/Output Grid Frequency/Range 50Hz/45Hz-55Hz     60Hz/55Hz-65Hz
Power Factor Adjustment Range 0.8 leading to 0.8lagging
Total Current Harmonic Distortion THDi <3% (of nominal power)
DC Injection Current <0.5%ln
Efficiency
Max Efficiency 97.6%
Euro Efficiency 96.5%
MPPT Efficiency >99%
Equipment Protection
Integrated
DC Reverse Polarity Protection, AC Output Overcurrent Protection, Thermal Protection, AC Output Overvoltage Protection,
AC Output Short Circuit Protection, DC Component Monitoring, Arc Fault Circuit Interrupter (optional), Anti-islanding
Protection, DC Switch, Insulation Impedance Detection, Residual Current Detection
Surge Protection Level TYPE II(DC),TYPE II(AC)
Interface
Communication Interface RS485/RS232/CAN
Monitor Mode
GPRS/WIFI/Bluetooth/4G/LAN(optional)
General Data
Operating Temperature Range -40 to+60℃,>45℃ Derating
Permissible Ambient Humidity 0~100%
Permissible Altitude 2000m
Noise <30
Ingress Protection(IP) Rating IP 65
Inverter Topology Non-Isolated
Over Voltage Category OVC II(DC),OVC III(AC)
Cabinet size(W*H*D)[mm] 376*470*241.5(Excluding connectors and brackets)
Weight[kg] 17.6 19
Warranty 5 Years/10 Years

the Warranty Period Depends the Final Installation Site of Inverter, More Info Please Refer to Warranty Policy
Type Of Cooling natural cooling
Grid Regulation IEC 61727,IEC 62116,CEI 0-21,EN 50549,NRS 097,RD 140,UNE 217002,OVE-Richtlinie R25,G98,G99,VDE-AR-N 4105
Safety EMC/Standard IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2

*For the SUN-3.6K-SG04LP1-EU-SM2, the maximum output current will be capped at 15.7A to comply with the G98 standard.